CO2 Incubator
MarkEn CO₂ Incubator is designed to provide a stable and controlled incubation environment for cell culture, tissue culture, and biological research applications. With precise regulation of CO₂ concentration, temperature, and humidity, it supports reliable growth conditions and consistent laboratory results. Its advanced contamination control, rapid recovery performance, and user-friendly monitoring system make it suitable for research, biotechnology, pharmaceutical, and clinical laboratory use.
Precise CO₂ Control
Advanced IR sensor technology ensures accurate CO₂ regulation, maintaining stable conditions for sensitive cell culture applications.
Uniform Temperature Stability
Air-jacketed heating and controlled circulation provide consistent temperature distribution throughout the chamber.
High Humidity Environment
Maintains humidity above 95% RH to reduce sample drying and support healthy cell growth conditions.
Enhanced Contamination Safety
HEPA filtration and 180°C sterilization cycle help maintain a cleaner chamber environment for critical applications.
Smart Monitoring Interface
Touchscreen display enables easy parameter control, real-time monitoring, data logging, and performance visibility.
Rapid Recovery Performance
Quickly restores CO₂ and temperature levels after door opening, ensuring stable incubation conditions.
Type | Advanced CO₂ incubator |
Application | Suitable for in-vitro cell culture and bacterial culture studies |
Capacity | 150 L |
Construction & Material | Outer chamber made of epoxy powder-coated mild steel with rust-proof SS 304 polished stainless-steel inner chamber for hygienic operation, durability, and corrosion resistance |
Chamber Design | Rounded corner chamber design for easy cleaning and contamination control |
Door Design | Solid outer door with inner glass door for full sample visibility without disturbing chamber conditions |
CO2 Concentration | 1-20% |
CO2 Range | 0–20% v/v |
CO₂ Control Resolution | ±0.1% CO₂ control resolution with IR sensing technology |
CO₂ Sensor | Infrared (IR) CO₂ sensor |
Temperature Range | 5°C to 60°C (±1°C), with accuracy of ±0.1°C at 20°C and uniformity of ±2.0°C. |
Temperature Performance | Maintains stable temperature at 37°C |
Temperature Sensor | Capillary Thermostat |
Shelves | 3 adjustable, removable, and washable shelves |
Control System | Advanced microprocessor-based PID control system with LCD display for precise, stable, uniform environmental regulation, parameter control, and real-time monitoring |
Alarm System | Independent audio-visual alarm system for temperature deviation, over-limit condition, door open duration, UV operation status, CO₂ concentration, and concentration difference alerts |
Recovery Performance | Fast recovery after 30-second door opening with recovery to 5% CO₂ in approx. 3 minutes and 37°C in approx. 8 minutes |
Air Circulation System | Automatic air circulation control for uniform temperature maintenance without internal fan turbulence or vibration |
Condensation Prevention | Door temperature controller prevents condensation formation on glass door |
Heating System | Air-jacketed hot-air sterilizing circulation system |
Dry heat sterilization | 180°C |
Power Supply | 220V, 50Hz single phase AC power supply |
CO₂ Accessories | Supplied with minimum two CO₂ cylinders, two-stage CO₂ gas regulator with barbed connection and shut-off valve, and built-in automatic CO₂ gas guard switching system |